#1
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Hi
I want to insulate CH 22mm pipes. The standard ''round'' pipe insulation will not fit because of all four pipes being to close together. I am thinking of covering the lot in expandable foam, maybe loosely wrapping something around them and spraying inside to contain the foam. I do not want to use any fibreglass/rockwool wraps as I am allergic to that stuff. Are the foam insulating properties as good as the pipe insulation tubes? Are there any other alternatives? Any advice greatly appreciated Peter |
#2
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
peter wrote:
Hi I want to insulate CH 22mm pipes. The standard ''round'' pipe insulation will not fit because of all four pipes being to close together. I am thinking of covering the lot in expandable foam, maybe loosely wrapping something around them and spraying inside to contain the foam. I do not want to use any fibreglass/rockwool wraps as I am allergic to that stuff. Are the foam insulating properties as good as the pipe insulation tubes? Are there any other alternatives? Any advice greatly appreciated Peter Sounds messy and expensive. Why not use the old fashioned felt lagging? Just wind it round all 4 instead of one. NT |
#3
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
or use this spiral wrap from screwfix. It is silver bubble wrap and is
designed exactly for your purpose. http://www.screwfix.com/app/sfd/cat/...62194&ts=16185 |
#4
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "jks" wrote in message ups.com... or use this spiral wrap from screwfix. It is silver bubble wrap and is designed exactly for your purpose. http://www.screwfix.com/app/sfd/cat/...62194&ts=16185 Equivalent to 33mm polystyrene!!!?!!? That'll be UNexpanded polystyrene then. -- Mike W |
#5
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
peter wrote:
Hi I want to insulate CH 22mm pipes. The standard ''round'' pipe insulation will not fit because of all four pipes being to close together. I am thinking of covering the lot in expandable foam, maybe loosely wrapping something around them and spraying inside to contain the foam. I do not want to use any fibreglass/rockwool wraps as I am allergic to that stuff. Are the foam insulating properties as good as the pipe insulation tubes? Are there any other alternatives? Any advice greatly appreciated Peter Sounds a very sound way to proceed to me. I'd say that its probably BETTER than foam sleeves. |
#6
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "The Natural Philosopher" wrote in message ... I am thinking of covering the lot in expandable foam Sounds a very sound way to proceed to me. I'd say that its probably BETTER than foam sleeves. I can just picture your shed or wherever you keep stuff. 'We saw Foam, lots of foam, lots of foam...' http://www.weebls-stuff.com/toons/magical+trevor/ Do you use anything else ;-) -- Mike W |
#7
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Thanks for all suggestions.
Just curious if the expanding foam gas same insulating properties per volume as pipe insulatoin? peter |
#8
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "peter" wrote in message ... Thanks for all suggestions. Just curious if the expanding foam gas same insulating properties per volume as pipe insulatoin? peter Products typically have a rating in watts per hour of energy transmission. But PU foam-in-a-tin can not because it depends how it is used. The user affects how aereated the foam is. However it will be roughly comparable to any PU foam product such as kingspan, look on there web site. Err on the lower side since their facilities obviously allow the best possible values to be achieved. -- Mike W |
#9
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Thanks Mike
Do you think that the claim that spiral wrap from screwfix is an equivalent to 33mm polystyrene not possible? rafal "VisionSet" wrote in message ... "peter" wrote in message ... Thanks for all suggestions. Just curious if the expanding foam gas same insulating properties per volume as pipe insulatoin? peter Products typically have a rating in watts per hour of energy transmission. But PU foam-in-a-tin can not because it depends how it is used. The user affects how aereated the foam is. However it will be roughly comparable to any PU foam product such as kingspan, look on there web site. Err on the lower side since their facilities obviously allow the best possible values to be achieved. -- Mike W |
#10
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "peter" wrote in message ... Thanks Mike Do you think that the claim that spiral wrap from screwfix is an equivalent to 33mm polystyrene not possible? I think whatever dimension that 33mm is supposed to apply to it is unlikely. If it refers to the usual wall thickness then it is extremely unbelievable. B.Reg for climaflex insulation rating works out to be 25mm. Expanded Polystyrene is going to be very similar if not better thermal efficiency. Foil backing may be effective but I don't believe it beats depth of something decent. -- Mike W |
#11
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In article , VisionSet
writes "peter" wrote in message ... Thanks Mike Do you think that the claim that spiral wrap from screwfix is an equivalent to 33mm polystyrene not possible? I think whatever dimension that 33mm is supposed to apply to it is unlikely. If it refers to the usual wall thickness then it is extremely unbelievable. B.Reg for climaflex insulation rating works out to be 25mm. Expanded Polystyrene is going to be very similar if not better thermal efficiency. Foil backing may be effective but I don't believe it beats depth of something decent. Agreed, the claims are complete pish. -- fred Plusnet - I hope you like vanilla |
#12
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Sun, 24 Sep 2006 22:01:16 GMT, a particular chimpanzee named
"VisionSet" randomly hit the keyboard and produced: "jks" wrote in message oups.com... or use this spiral wrap from screwfix. It is silver bubble wrap and is designed exactly for your purpose. http://www.screwfix.com/app/sfd/cat/...62194&ts=16185 Equivalent to 33mm polystyrene!!!?!!? That'll be UNexpanded polystyrene then. I was sceptical too, but it appears to be correct. The R-value of Alreflex (the nearest equivalent I could think of) with no cavity either side is 0.15m2K/W; the R-value with cavity both sides is 1.56, so the R-value with one side exposed must be 0.93. Multiply that figure by the conductivity of polystyrene (0.037W/mK) and the equivalent thickness is 34mm so they're not far off. -- Hugo Nebula "If no-one on the internet wants a piece of this, just how far from the pack have you strayed?" |
#13
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Sat, 30 Sep 2006 22:38:05 +0100 Hugo Nebula wrote :
or use this spiral wrap from screwfix. It is silver bubble wrap and is designed exactly for your purpose. http://www.screwfix.com/app/sfd/cat/...62194&ts=16185 Equivalent to 33mm polystyrene!!!?!!? That'll be UNexpanded polystyrene then. I was sceptical too, but it appears to be correct. The R-value of Alreflex (the nearest equivalent I could think of) with no cavity either side is 0.15m2K/W; the R-value with cavity both sides is 1.56, so the R-value with one side exposed must be 0.93. Multiply that figure by the conductivity of polystyrene (0.037W/mK) and the equivalent thickness is 34mm so they're not far off. Note that the following BRE document casts doubt on the TRADA figures being quoted for this sort of insulation http://www.planningportal.gov.uk/PpW...n_july2005.pdf -- Tony Bryer SDA UK 'Software to build on' http://www.sda.co.uk |
#14
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Sat, 30 Sep 2006 23:29:09 +0100, a particular chimpanzee named Tony
Bryer randomly hit the keyboard and produced: On Sat, 30 Sep 2006 22:38:05 +0100 Hugo Nebula wrote : I was sceptical too, but it appears to be correct. The R-value of Alreflex (the nearest equivalent I could think of) with no cavity either side is 0.15m2K/W; the R-value with cavity both sides is 1.56, so the R-value with one side exposed must be 0.93. Multiply that figure by the conductivity of polystyrene (0.037W/mK) and the equivalent thickness is 34mm so they're not far off. Note that the following BRE document casts doubt on the TRADA figures being quoted for this sort of insulation http://www.planningportal.gov.uk/upl...n_july2005.pdf That's for multi-foil insulation which tries to claim R-values equivalent to 200mm of rockwool. Alreflex is bubble-wrap sprayed silver. The R-value includes a value for the material as well as increased resistances of the air either side as it has a higher emissivity (or is it lower?, it's late & I can't remember). The values I quoted were taken from the BBA certificate for it, so if you can't believe them, who can you believe?! -- Hugo Nebula "If no-one on the internet wants a piece of this, just how far from the pack have you strayed?" |
#15
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In article , Hugo
Nebula abuse@localhost.? writes On Sat, 30 Sep 2006 23:29:09 +0100, a particular chimpanzee named Tony Bryer randomly hit the keyboard and produced: On Sat, 30 Sep 2006 22:38:05 +0100 Hugo Nebula wrote : I was sceptical too, but it appears to be correct. The R-value of Alreflex (the nearest equivalent I could think of) with no cavity either side is 0.15m2K/W; the R-value with cavity both sides is 1.56, so the R-value with one side exposed must be 0.93. Multiply that figure by the conductivity of polystyrene (0.037W/mK) and the equivalent thickness is 34mm so they're not far off. Note that the following BRE document casts doubt on the TRADA figures being quoted for this sort of insulation http://www.planningportal.gov.uk/upl...n_july2005.pdf That's for multi-foil insulation which tries to claim R-values equivalent to 200mm of rockwool. Alreflex is bubble-wrap sprayed silver. The R-value includes a value for the material as well as increased resistances of the air either side as it has a higher emissivity (or is it lower?, it's late & I can't remember). The values I quoted were taken from the BBA certificate for it, so if you can't believe them, who can you believe?! Although the BRE report refers to multilayer I believe that the failings pointed out apply to all products that (over) rely on reduction in radiation for their 'enhanced' properties. The easy flaws to spot a 1. They rely on a carefully controlled air gap to meet their stated performance. 2. The gap must be still air or heat will lost by conduction to the moving air (forced convection if you like), so no draughts and no ventilated roof or cavity. 3. The gap has an optimum width, too great and there is room to create a convection loop giving more heat loss. 4. The reduced radiation relies on clean reflective outer surface, get it dirty or dusty and there goes the radiation benefit resulting in more heat loss. 5. The reflective surface may lose its shine with age resulting in more heat loss. To stand a chance of this product getting close to its design claims you have to install it in an unrealistically perfect environment. In contrast, trapped air systems (foams, rockwool or whatever) can achieve high performance with a lot less attention to detail. -- fred Plusnet - I hope you like vanilla |
#16
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Sun, 01 Oct 2006 00:50:22 +0100 Hugo Nebula wrote :
The values I quoted were taken from the BBA certificate for it, so if you can't believe them, who can you believe?! The document I cited relates back to results produced by TRADA: "if you can't believe them, who can you believe?!" -- Tony Bryer SDA UK 'Software to build on' http://www.sda.co.uk |
#17
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Sun, 01 Oct 2006 22:10:14 +0100, a particular chimpanzee named Tony
Bryer randomly hit the keyboard and produced: On Sun, 01 Oct 2006 00:50:22 +0100 Hugo Nebula wrote : The values I quoted were taken from the BBA certificate for it, so if you can't believe them, who can you believe?! The document I cited relates back to results produced by TRADA: "if you can't believe them, who can you believe?!" The problem with the TRADA document is that they don't have the accreditation to test for insulation values; so one couldn't believe them WRT insulation. -- Hugo Nebula "If no-one on the internet wants a piece of this, just how far from the pack have you strayed?" |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Foam vs Batt insulation when MOLD present | Home Repair | |||
pls help w/ rigid foam insulation install ... | Home Repair | |||
Is it possible to find wire insulation faults without a visual exam? | Home Repair | |||
undoing cast iron soil pipe joint | UK diy | |||
Ground to Gas Pipe?? | Home Repair |