Default compression fittings..... pah!

wrote:
Lobster wrote:

Pet wrote:

My tip for these PITA inventions is compress them up then undo them and
coat the olive in a healthy dose of Fernox-LSX silicone or similar.

Spent many hours Saturday faffing around behind the newly fixed basin &
pedestal with a tissue trying to find several weepers.

Silicone (as above) and a cup of tea while it cured did the job a treat.


Not how they are designed to work though: I hope they hold in the long term!



Yes, strange. After fitting 2 loos, basins, bath and kitchen I ended up
fitting about 20 compression onto new and (and sometimes used) olives,
with no leaks ever. Maybe he stopped tightening when he heard it
creaking. I tighten to the creak, then another 1/8 turn. Stop.


I generally find that there's no need to tighten that much - after all
its easy enough to nip them up a bit if the weep, but there's not much
you can do if you over-tighten them and damage the olive.