View Single Post
  #2   Report Post  
Leonard Caillouet
 
Posts: n/a
Default

Should be 130VDC. Check C916.

Leonard

"Dave Moore" wrote in message
.. .
Hello,
I just fixed this Mitsu CS-3506 in a trade deal with
a friend of mine. Crikey after replacing every
Nichicon black cap with a " + " stamped into the
top of the can and also hours of reworking electrolyte
damaged traces I think I'm about ready to make the
drive and put the chassi back into the set.

Before I pulled the chassi out, I measured B+
to the HV section to be 149 V
None of the Mitsu schematics I have for other sets
indicate any B+ this high.
Could this be normal for this model,
or should I take a closer look at the SMPS
regulation before I reinstall the chassi
and fire this puppy up?

Thanks,
Dave