I read that it is not a good idea to have too many thermostatically
controlled radiator valve as it cuts down the efficiency but we only
have them in bedrooms.


Not really a problem with a modulating boiler since it simply reduces
its power output to mathc the reducing load, hence it maintains
operation in an efficent temperature range.


It is a problem. You need a by-pass valve which raises the return
temperature which reduces efficiency. You can get around this by isntalling
a flow switch abd timer. By-pass valves should not be on condesning boilers