View Single Post
  #10   Report Post  
Lee
 
Posts: n/a
Default Video player won't 'play' ;-(

T i m wrote:
On Tue, 23 Mar 2004 08:15:41 -0000, "Graeme"
wrote:



My HD600 was recently ressurected after I replaced the small worm gear on
the end of the load motor. This had become cracked and I've been told that
this is common. Open your machine and inspect this item.



Hi Graeme,

Now you mention it .. I think I actually did this a few years ago (but
not for same fault) and *may* have another spare taped to the top of
the unit. As you say .. worth a peek though ;-)


It was late, talking to myself is usual

Your model has a "K" deck.
F03 and F06 both point to either a spilt worm gear or a misalinged deck.
You may also find this link helpful:
http://www.e-repair.co.uk/story4.htm

If the worm gear is ok, suspect the mode switch...

Lee
--
To reply use lee.blaver and ntlworld.com