On 12/15/2004 5:57 PM HorneTD wrote:

Mike Rocket J. Squirrel Elliott wrote:

Can't get the Leviton site to work for me.

I've just installed their 5225-WSP Combination Switch and Receptacle.
This is the older, non-Decora, style which fits a normal duplex outlet
wall plate. This item is a Grounding type, with the third hole in the
front. The house does not have grounding wires. In California, it is
not required to upgrade, but you can't use three-hole outlets unless
grounding is provided. Does anyone know the Leviton product line well
enough to know if they make a non-grounding version of this
switch/receptacle? Or, alternately, whether it is acceptable to plug
the third hole with . . . oh, I don't know . . . chewing gum or JB
Weld or suchlike?



They make a combination switch GFCI on a single yoke that you could use
in place of the switch receptacle. GFCIs are acceptable as replacements
in outlet boxes that have no ground in the enclosure. You can see the
device at
http://www.levitonhelpdesk.com/catal...lityConnec t=


Thanks Tom. This is a non-Decora application. It's a three-gang box
with two regular non-grounding duplex receptacles and one Leviton 5225
grounding-style combo switch/receptacle in it. I don't want to change
out all the receptacles to accomodate one combination switch/receptacle
in Decora style, I just want to find a non-grounding version of the
combo part.

--
Mike "Rocket J Squirrel" Elliott
71 Type 2: the Wonderbus
84 Westphalia: "Mellow Yellow (The Electrical Banana)"
KG6RCR