View Single Post
  #32   Report Post  
Don Foreman
 
Posts: n/a
Default

Those controllers use the temperature-dependent resistance of the
heating element itself to sense temperature. In order to be accurate
they would have to be driving a heating element they were specifically
designed to work with.

On Thu, 02 Dec 2004 11:06:22 GMT, Gunner
wrote:

On Thu, 02 Dec 2004 08:56:10 GMT, Gunner
wrote:

Ive got a ****load of new temp controllers. Want one? They are analog
temperature holding, IRRC 220vac.


These look identical though mine have an additional alarm output

http://www.borkelectronic.dk/NET_Ser.../RES-210_e.pdf

the 220 shows the alarm switch and wiring
http://www.borkelectronic.dk/NET_Ser.../RES-220_e.pdf

Gunner