In message , manoman
writes
I would really appreciate it if you guys could look at this a see if I have
I missed anything obvious?

Cable:

3core x 4mm Armoured Black 25m Coil
BW20S Indoor Gland Kit


2.5mm T&E 100m Reel

Big garage :-)

Power Sockets

13A Double Switched Socket x 4
2G 32mm Square Corner Socket Box x 4

Metal clad I assume?

Mini Consumer Unit:

Garage Unit 40A/30MA + 16A,6A MCB

i'd have gone for a 20A for the sockets 'just in case' if possible, but
probably doesn't matter.

Light Switches for 2 zone lighting:


I'd run the cable in conduit. It gives the cable some extra protection
from damage, and it makes a much neater job, takes a little bit longer
and costs a bit more, but not dreadful.
--
Chris French, Leeds