"S Rao" wrote in message
om...
I have a Kenmore Water Softener ... Model Number: 625.348491 ... and
a few days ago I noticed that my Salt Brine Tank was almost full of
water.

I went to the Kenmore animations site for troubleshooting .... .and
came to the following conclusions:

== in the FILL mode ... water trickles into the float assembly thro'
the brine line (as it should)
== but when I go into the BRINE cycle .. water continues to trickle
into the float assembly . If i am not wrong .. water should stop
flowing thro' the brine line into the float assembly
== so i undid my venturi valve .. and noticed the gasket and the flow
plug worn out. so i replaced them. i also replaced the (2) flow plugs
.. to be on the safe side.
== but when I put the venturi valve back together .. water continues
to drip into the float assembly even in the BRINE cycle (which is why
it is flooding my salt tank)
== in the BRINE cycle .. i disconnected the Brine line off the bottom
of the venturi assembly. instead of feeling suction at the venturi
assembly fitting .. water is coming out of the venturi assembly
fitting
== what else could be wrong; everything else in the venturi assembly
looks good .. including the screens and the o-ring

would appreciate any pointers help from others ..

eb7380


Vacuum that brine out of there pronto and lift out all but 10-20 lbs of the
salt--then re-assess the situation.

You make brine ( water goes into the salt tank ) then you charge the resin
bed by vaccumming it back out of the salt tank and into the resin
cannister........subsequent cycle is to flush excess salt/ debris out of the
resin bed, and will rarely cause problems......

The venturi needs to suck all the brine out of the salt tank--you should be
able to put your thumb over the tube during this second stage and feel
suction..........If not, or if there is liquid escaping under pressure
instead theres a problem with the venturi or the valve assembly, and
recharge of the resin bed is gonna be happening.........

By the time this is all complete, the venturi should be only sucking air,
and the very bottom of the salt tank should be pretty much devoid of any
measureable liquid.

In short, it appears there is most likely still a problem with your brine
intake.

--

SVL