I am under the impression that supplementary bonding in the kitchen is
now out! Just the earth bonding to main gas/water pipes and the works
in the bathroom!

On Sun, 05 Sep 2004 22:51:25 GMT, "Lobster"
wrote:

"Andy Wade" wrote in message
.. .
Bob Eager wrote:

Years ago, I did this on a stainless steel sink by drilling a hole in
teh side (the vertical part) in an inconspicuous corner. I then crimped
a tag to the earth cable and bolted it on, using said hole. This was
done inside, so only the bolt head was visible outside.


Another way is to use the type of earth clamps made for connecting to
thin metal sections, such as Eze-earth - shown here as type TZB100:


http://www.tlc-direct.co.uk/Main_Ind...lamps/index.ht
ml

or a Screwfix equivalent:
http://www.screwfix.com/app/sfd/cat/pro.jsp?id=18129&ts=12208.


Thanks - in fact I already have some of the Screwfix ones; however there's
no suitable rib or edge that I can see where I could fit one of these. Even
so, I was looking at one and couldn't work out how I would attach the cable
even to these! The screw terminal is tiny - certainly compared with the h/d
screw on a conventional pipe earth clamp. Is the answer that you have to
crimp on a tag, as suggested by Bob above? If so I guess I need a crimping
tool, then...

David