On 26/05/2021 12:51, Fredxx wrote:
On 26/05/2021 11:56, R D S wrote:
On 25/05/2021 11:48, fred wrote:
Serious explosion bellied caused by cut gas pipe. How ? Presumably it
was in error but what would you be doing for that to happen?


We've no gas to our kitchen (meter at opp end of house) and I've never
been motivated to rip up the floor throughout to sort it.

My neighbours have taken a pipe out of the meter cupboard door and run
it along the floor/skirting.


I don't think you can route a new gas pipe under floorboards.


I'm pretty sure you can.

My understanding (not that I actually have anything to do with gas) is
that a new supply pipe to the meter should not be routed under the
property, but for pipes after the meter - under a suspended ground floor
is fine (it is classed as a ventilated space), while, in an unventilated
floor/ceiling void needs a surrounding sleeve, with one end sealed and
the other end open to a ventilated space.