View Single Post
  #51   Report Post  
Posted to uk.d-i-y
Roger Hayter[_2_] Roger Hayter[_2_] is offline
external usenet poster
 
Posts: 3,237
Default Connecting polypipe to lead pipe

Roland Perry wrote:

In message , at
11:59:49 on Sat, 2 May 2020, Robin remarked:

No big deal to connect lead to copper using solder. For a decent plumber.
The consensus is that this is now banned for potable water.

And copper to plastic then gets you into not needing a decent
plumber.


One thing I've learnt in this thread is that there's probably no
such thing as a lead-polypipe connector. You have to go via copper.


I've read the thread as pointing to either copper soldered to lead


which isn't allowed.

or a lead-lock; and you can use lead-locks to plastic pipe (with insert
where appropriate).


Indeed. But is there no such thing as a poly-lead leadlock?

It's not a huge issue, other than trying to get the plumber to put one
(or two) on his van before he arrives.


You can put polypipe in a standard compression fitting for copper tube.
I believe copper olives are preferred, but you can get loose copper
olives easily. And obviously you must use a pipe insert. I suspect
the end result is more reliable than a push fit connector.


--

Roger Hayter