On 2019/12/09 11:22 a.m., Chuck wrote:
On Sun, 8 Dec 2019 08:38:51 -0800 (PST), Stu jaxon
wrote:

Hi Group, can someone help please? I was working on a Hisense 40" LED TV, Testing the CAPS in circuit with the power on(plugged in), with the MESR-100 v2.3 meter and accidentally crossed the leads on the meter testing a cap, on the power supply and as far as i know, I only blew the fuse on the board, I removed 8 caps from the board and tested them with the meter and they all tested -0.00 I know that is not a correct reading, when initially turning on the meter it supposed to read OL now reads .729... so i tested the caps with a DMM and found three bad caps. can this meter be fixed?? any suggestions on this matter will be taken seriously, Thanks..

If you buy another ESR meter without voltage protection, try putting 2
power diodes in parallel across the input. Tie the cathode of one to
the anode of the other. It has protected my Bob Parker meter for
years.


Bob Parker meters are good to 50VDC...

John :-#)#

--