Default Thermostatic mixing valve problem

But is that not the whole point of this exercise, so that you don't need to
worry about the temperature?
Brian

--
----- --
This newsgroup posting comes to you directly from...
The Sofa of Brian Gaff...

Blind user, so no pictures please
Note this Signature is meaningless.!
wrote in message
...
On Thursday, 10 October 2019 10:08:08 UTC+1, Tim+ wrote:
A while back a friend asked me if there was any way he could have a warm
water supply outside for washing his dog.

As there was easy access to hot and cold supplies inside I fitted one of
these.
https://www.bes.co.uk/thermostatic-m...-3-15mm-12162?

Before purchase I checked with the manufacturer that it was suitable for a
mixed mains pressure cold feed and gravity fed HW.

It worked fine for several months but then water stopped coming out of the
tap. Sometimes if you waited the flow would start and it would produce
premixed warm water. Eventually it stopped working altogether.

Thinking that he'd just been unlucky my friend opted to buy a new valve
and
now a month after fitting the same thing is happening. All rather
annoying.

Before fitting the new valve I blew through the non-return valves and
discovered that they needed a fair bit of pressure to persuade the valve
to
"crack open" the first time, after that they seemed to open reasonably
easily.

It seems likely to me that the HW non-return valve is sticking on its
seat,
perhaps because it's being exposed to reverse mains pressure cold water
when the outside tap is off.

Now I'm sure I could disassemble the things and blow through the valve
again to free it but I would really rather not have to keep doing this.
One thought that occurs to me is that if I could think of a simple way to
produce an upstream "pressure pulse" above the non-return valve I could
pop
it off it's sticky seat.

Long term answer may be to just go back to external H & C taps but he does
like the pre-mixed warm water.

Any suggestions?

Tim


So fit a mixer tap without the tmv.


NT