View Single Post
  #9   Report Post  
Posted to uk.d-i-y
Roger Hayter[_2_] Roger Hayter[_2_] is offline
external usenet poster
 
Posts: 3,237
Default Orientation of bib taps?

ARW wrote:

On 16/05/2019 18:09, Adam Funk wrote:
On 2019-05-16, Jim K.. wrote:

Adam Funk Wrote in message:
Just to be clear, I'm talking about combining these two parts:

Compression Wallplate Elbow 15mm x 1/2"
https://www.toolstation.com/compression-wallplate-elbow/p74070

Hose Union Bib Tap with Double Check Valve 1/2" DZR
https://www.toolstation.com/hose-uni...ble-check-valv
e/p54792

I was under the impression that if you install the elbow so that
supply pipe is coming straight down to it, the tap should screw all
the way into it & end up pointing down. (I'm pretty sure that's what
I did with the old ones, which were removed as part of a kitchen
renovation, so I've installed new ones in a different place outside.)

In practice, however, I installed two of these the same way but they
ended up pointing in slightly different directions, neither straight
down. I ended up packing a couple of fibre washers in each elbow
until I got the right direction. What am I missing?

Thanks.


Ptfe tape?


I tried it with and without PTFE tape on the threads. Both ways, the
tap went in farther than I expected, ending up pointing down and left
rather than just down.


I believe Jim meant make your own washer with ptfe, not wrap it around
the threads.


Or you can wind the PTFE tap on the threads progressively thicker near
the back of the fitting until the threads jam at the point you want them
to.

--

Roger Hayter