View Single Post
  #24   Report Post  
Posted to alt.home.repair
Arlen Holder Arlen Holder is offline
external usenet poster
 
Posts: 193
Default Water pressure booster pump won't start consistently - do you rebuild the bearings?

On 14 Aug 2018 06:24:36 GMT, Arlen Holder wrote:

*It's "FR 56C"*


That makes things infinitely easier to look up for replacement because this
is all that matters, I think.
http://www.bild.me/bild.php?file=2105511pressure05.jpg

1. Horsepower = 1HP with a service factor SF of 1.4 (i.e., 1.4HP full load)
2. Frame = 56C
3. Power = 120VAC single phase
4. Locked rotor code = L (9 to 10 volts)

With that, the first hit is this $261 motor:
http://www.electricmotors.com/1hp-3600rpm-nol-56cb-frame-jet-pump-motor.html

Reference on the service factor (SF):
http://www.inyopools.com/Blog/is-a-1-0hp-motor-the-same-as-a-1-5hp-motor/

Reefernce on the locked-rotor code (L):
http://www.arescobuyersclub.com/nameplates.html