Thread: Dimmer and LED
View Single Post
  #2   Report Post  
Posted to uk.d-i-y
Dave Plowman (News) Dave Plowman (News) is offline
external usenet poster
 
Posts: 43,017
Default Dimmer and LED

In article 2,
DerbyBorn wrote:
I have just had a touch dimmer fail.


I had used it to control a bar with 4 x 50 watt GU10s.


I replaced with LEDs and ov course it wouldn't work as it had a 40watt
minimum load requirement.


I put a Halogen back in and it worked - but after a while the dimmer
failed. Could this be due to it seeing a mixed load?


I have now replaced the dimmer with one that says 4 watt LED min.


Dimmable LEDs usually need a trailing edge dimmer. Depending on design,
long before LEDs arrived, some were but most weren't. I've got MK grid
dimmers in one room fitted in the late 80s, and they are fine with LEDs.
But other much newer ones which had to be changed.

So saying, I'm not sure why a LED would cause the dimmer to fail. Where
I've mixed tungsten and LED with an 'old' dimmer, the LED just failed to
dim.

--
*On the seventh day He brewed beer *

Dave Plowman London SW
To e-mail, change noise into sound.