View Single Post
  #4   Report Post  
Posted to sci.electronics.repair
N_Cook N_Cook is offline
external usenet poster
 
Posts: 5,247
Default Blocked ink-jet nozzles

On 23/10/2017 15:22, wrote:
On Monday, October 23, 2017 at 9:42:45 AM UTC-4, N_Cook wrote:

2 minutes in an ultrasonic bath ,canted over to the yellow side, in
methylated spirits. Both now fine photo-grade output, with refilled carts.


Yes. Ultrasonic cleaners can be very close to magic if properly applied.

Peter Wieck
Melrose Park, PA


Mine gets very little use, but the top, conveniently glass for would-be
viewing, is all crazed/micro-fractured?
Is that common with such cleaners, partially self destructing?
If I want to see whats going on, I have to find a piece of glass or
perspex to cover over the dancing fluid fountains.

I should have said , with the damp tissue test, showing yellow staining
on the tissue. Also locked-in , meaning makers trying to defeat cart
refilling, to force purchase from them.
Another tip, I don't see with ink refill kits, they always seem to say
drill in . That must leave plastic swarf inside. I use a conical
soldering iron tip at the breather hole , to melt in. Then when closing
, a short length of spaghetti tube inserted and then hot melt glue
around it and marginally into the plastic of the cart, so easily pulled
away the next time.