JoeJoe wrote:
I have quite a few of these in my kitchen, used with 50W MR16 bulbs and
transformers (one per light):
http://www.ebay.co.uk/itm/HQ-Halogen...terproof-For-M
R16-Lamps-Max-50W/112184915408
and
http://www.free-instruction-manuals....f/p4734235.pdf
According to this they are rated 12v AC, and should only be used with
MR16 bulbs.
I would like to replace the transformers + bulbs with mains GU10 LED
bulbs instead.
Any reason why this shouldn't be done?
PS: they are a pretty old model (mine were bought 10+ years ago), and
are no longer available, so well before LED downlights became available.
I've done it with a similar but more elaborate MR16 12V halogen
downlight. There was a bit of bodging to replace the MR16 socket, which
was riveted to the frame, with a GU!0 socket (c/w heat resistant flying
leads - from Ebay) but as long as the chocolate block connector is
protected and fixed, with a cable clamp and a cover to avoid shock in
accordance with wiring regulations I see no problem with it.
--
Roger Hayter