Thread: PLayStation ll
View Single Post
  #2   Report Post  
Mike
 
Posts: n/a
Default PLayStation ll

yep.

There is a BAxxxx IC that typically overheats if removed from its heatsink
and it knockes out a chip fuse with a "50 marked on it.

PS11. check it. it might be open. if it is, the BA IC next to it is your
trouble, there is also a ton more on there. Check all chip fuses that have
an arrow pointing to them labled PSxx, those are fuses.




"WickBros" wrote in message
...
Workin on a PS2 that was knocked off a table with about 2 ft drop on
linoleum, only damage was the cd tray front cover broke off, but it still
functioned, Owner thought he could work on it himself, I noticed that the
reset/eject ribbon cable had been pretty mangled, and all I did was to
re-align the laser focus, had it opened and spread apart on bench and

played
like 6-7 DVD's on it solid with no prob. In re-assembling it after I was
confident in it, the ribbon cable finally gave out as I was putting the

lid
on it, well ordered a new one, put it in, tryed to power it up and now I

get
nothing, p-supply out voltages seem norm, but yet its "dead in the water",
no lights,eject,video
there a SMD fuse or a reset button hidden somewhere???
TIA!!




-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 100,000 Newsgroups - 19 Different Servers! =-----