Ultrasonic cleaning of Brass- corrosion of stainless?
On Tue, 26 May 2015 06:59:41 -0700, "Gary A. Gorgen"
wrote:
On 05/26/2015 06:33 AM, Spehro Pefhany wrote:
A friend is cleaning brass prior to reloading in an ultrasonic cleaner
using an old formula-
1 qt H20
1 cup vinegar
1 Tsp salt
1 Tsp soap
Seems like a couple of the pans have corroded through on different
brands of unit- destroying the ultrasonic cleaner. The brass should
not be in contact with the pan (there's a stainless basket, or plastic
in the 3rd one he's trying).
Any reason why this would happen? There's not that much difference
between (presumably 400-series) stainless and brass on the
electrochemical series.
Thanks for any leads..
If the brass is touching the bottom of the tank, the tank will
erode. The brass is acting like a 20 KHZ jackhammer.
I used to build ultrasonic cleaners, the 1 KW+ type.
They do have a tendency to self destruct.
Got a RinoLiner in your friends area? Have em give it a quick coating
on the inside.
|