Protecting against transient blown lighting fuse
On 14/11/2014 00:30,
wrote:
On Thursday, November 13, 2014 11:35:00 PM UTC, Toby wrote:
On 13/11/2014 01:58,
wrote:
On Wednesday, November 12, 2014 8:22:45 PM UTC, Toby wrote:
On 12/11/2014 14:13, Adrian Caspersz wrote:
On 12/11/14 14:09, Dennis@home wrote:
On 12/11/2014 13:53,
wrote:
My tenants in the shop have called me out for the third time because the
lighting fuse blew when they turned on their miniature halogen
chandelier
and one of the lamps blew at switch-on. To me, continuously blowing
fuses
means a faulty appliance, and in this case I definitely blame the
halogen
chandelier. I hate the things. I should never have installed it for
them,
but they'd already bought it and "it looks sooooo nice!!!".
Put a dimmer on the chandelier as they usually have soft start so less
chance the lamps will blow and take out the fuse.
The lamps will take out the dimmer instead ....
Not this one, it is fine for halogens at its advertised rating (I have
200w of GU10 on one without any issues at all).
http://www.tlc-direct.co.uk/Products/VLIS1401.html
No dimmer is flashover-proof.
Not sure why that is relevant to this part of the thread, if the OP puts
that dimmer on, which has soft start, and leaves the 5A fuse in place, I
expect it will be enough to prevent the fuse from blowing.
Soft start doesn't prevent filament bulbs blowing, doesn't extend their life significantly and doesn't prevent arcover.
Soft start does actually extend the life of halogen lamps. You may find
you can swap the circuit fuse going for the dimmer fuse (or the dimmer!)
--
Cheers,
John.
/================================================== ===============\
| Internode Ltd -
http://www.internode.co.uk
|
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
Reply With Quote