"Baron" wrote in message
...
Chris B. prodded the keyboard


CAP, FXD, CER DI : 0.022 uf 20% 50V


Its not a critical component. 0.022 uf is a common value and 50Vw
is typical. Try RS components or Element 14, Mouser there's lots
to go at.


So presumably the cap failed and caused the resistor to char.


That's about the size of it !

I'm thinking of ordering a bunch of these:


http://www.digikey.ca/product-detail...844-ND/3726082


I wouldn't ! The link shows 22 pf as the value.

--
Best Regards:
Baron.


He
http://www.digikey.ca/product-detail...5-1-ND/1913290