Predictions on all the freon leaked out (followup two)
On Thursday, May 22, 2014 10:02:51 PM UTC-4, Stormin Mormon wrote:
Return to the house. Brought my brushes, shop
vac, cleaning chemicals. HO provided electricity
through a window and around. And garden hose.
Pull the unit apart. Brush and vacuum the dry coils.
Apply coil cleaner, and wait. Rinse, repeat.
Set thermostat for cooling, and weigh in 1# 8z
of R22. Suction pressure about 19 PSIG. Didn't
read the high side.
Indoors ambient 73, vents about 64.
They will run for a couple days, and see if the
freon holds. I suspect it will.
Advised customer, that's not really enough R22 to
be proper, but we'll test it for a couple days and
see if it all leaks out. Yes, I beeped for leaks.
No, I didn't find any leaks.
If there are no leaks, where did all the freon go?
|