On 2013-12-08, Jim Wilkins wrote:
"Ignoramus31823" wrote in
message ...
On 2013-12-07, Jim Wilkins wrote:
Check valve from compressor to primary tank, another from secondary
to
primary. Normally-closed solenoid valve from compressor to
secondary,
opens when primary 90PSI. Can be switched off. Primary feeds shop
air
line....

jsw


This is EXACTLY what I wanted to do, except the filling valve should
open at 120 and close at 90. Thanks for explaining.

i


90PSI was a placeholder to simplify the explanation.

Your unloader may require another check valve going into the secondary
tank.


Right. I already found two 1/2 inch check valves, with manual valves
on them also. If I do add a tank it should work out pretty good.

i