On 06/14/2013 04:05 PM, N_Cook wrote:
Remove and shake it all about, the developer gets clumpy and blocks
normal rotation of the material

See the other posting for the solution.
BTW, this model does not have the classical developer/toner system
anymore. There is just a toner box saturating a roller (with an excess
wiper) which on the other side touches the drum.