Lieutenant Scott wrote:
On Sat, 05 Jan 2013 11:30:14 -0000,
wrote:

Lieutenant Scott wrote:
On Fri, 04 Jan 2013 13:14:54 -0000,

wrote:


Snip

Sorry I've been away so long!!

Your diagram is not going to happen.....ever!!

Primary power = 240 Vp times 1.5 Ip equals 360 Watts
Secondary power = 120 Vs times 3.0 Is equals 360 watts

Secondary power equals Primary power, so no (i.e. zero, zilch) power
can
be dissipated in the top half of the transformer, so zero voltage
developed across the top half of the transformer, so Vs must equal Vp,
i.e. 240 V not the 120 V your diagram shows.

Not going to happen....ever!! Sorry!!

Daniel

It was simply a rough diagram to work out the approximate current flow,
I was assuming no losses!


In my calculations I was assuming no losses, too, so it doesn't work, in
any case.

Daniel


The diagram I drew at
http://petersphotos.com/temp/transformer.jpg makes
perfect sense to me.

If you create a secondary coil in the lower half and seperate the two
circuits, it's just like a normal transformer.


If.....If.....If

What you drew *Will not* work! No if's, no but's, no maybe's!!

Daniel