On 23/09/2012 15:13, Jim K wrote:
So what's the correct approach?
Taped up Terminal block poked up into void with feeds to fitting's
terminals,
Commonly seen, but not nice...
Choc box into void & similar?
Yup, that is fine. Basically you want a proper enclosure round the
joins. Wago boxes and terminals are nice. There are also some proper
matin connector systems that allow the fixture to plug into the "rose"
in the ceiling void)
http://cpc.farnell.com/jsp/search/re...questid=464292
--
Cheers,
John.
/================================================== ===============\