Thread
:
Schottky barrier diodes testing
View Single Post
#
12
Posted to sci.electronics.repair
mike
external usenet poster
Posts: 634
Schottky barrier diodes testing
On 7/22/2012 10:02 AM,
wrote:
I also have two adjustable current power supplies like you mentioned.
So in other words, what you're saying is reverse bias the diode across
the supply, (cathode to positive) and look for leakage as read on the
current meter? Lenny
Correct, with precaution of using a current limiting supply or
increasing the voltage slowly.
PlainBill
Beware using current limited supplies to test stuff, especially junctions.
You can set the current to zero, but the energy stored in the
output capacitor can zap the device. Suggest using an additional
series resistor such that the open circuit voltage can support
no more current than the device can handle.
Reply With Quote
mike
View Public Profile
Find all posts by mike