Samsung P5-50C96HD Plasma TV
Les Matthew wrote in message
...
On 22/05/2012 12:14, N_Cook wrote:
First large "flat" TV I ever look at and its a plasma one. Dust never
cleaned off the rear grills and a visibly blown cap in the ps. Anything
to
be aware of, concerning any likely stored voltages/ safe discharge/
reconnecting headers as there are loads of 275V rated caps on the other
boards, before/after removing the ps .
Other than never hold / lean against the front panel, and no bending of
my
back for lifting /carrying, any other service advice specific to large
panel TVs?
Cycles continuously through coming on and relay clicking off , starting
up
again
Out of interest, was it manufactured some time in 2007?
I ask because I've just replaced eight out of the nine electrolytics on
the psu board of a Syncmaster 2232bw flat panel monitor that was
manufactured October 2007. All swelling and showing signs of leakage.
I have a second 2232bw in the bedroom that I'm going to change them all
too as a matter of course. CapXon is the make of the caps.
Les.
Dates of 2007 around it. 2 swollen/burst + one poor ESR all 105 deg C ,Low
V, replaced, not had time to power up again. At least there is plenty of
space in these sort of things for different footprint or taller caps as I
like to replace with next higher voltage.
|