View Single Post
  #16   Report Post  
Posted to rec.crafts.metalworking
JR North JR North is offline
external usenet poster
 
Posts: 399
Default [OT]: Refridgeration compressor question...

Can't do it. The compressor is cooled and lubed by the refrigerant and
oil charge. It will overheat quickly without it, and the thermal
shutdown activates.
JR
Dweller in the cellar

On Sun, 25 Sep 2011 19:31:44 +0800, "Dennis"
wrote:

I picked up a small fridge compressor with the idea of playing around using
it for a vacuum pick up tool for small electronics parts, but it behaves
strangely.

On initial power up it runs fine, very quietly.

It quickly/easily pulls down to 20kpa (-80kPa).


However if I disconnect the power and reconnect there is a quiet hum like
the motor is stalled (motor is not running & there is no airflow).


If I disconnect again then wait a minute or two before reconnecting it
powers on fine and will run fine - I've let it run for 5 minutes
continuously with no problems.


As part of the terminals to the motor there appears to be a thermal overload
switch, it gets warm but not hot (my guess ~30 Celius)



Heres a link to the data sheet:

http://www.transtech-co.jp/electroni...ompressor7.pdf



I vaguely recall something about fridges having protection against rapid
cycling of the power for some reason - but that could be rubbish. If there
is some sort of anti-short cycle timer it must be inside the compressor
housing itself.


Any ideas?



Thanks.

HOME PAGE:
http://www.seanet.com/~jasonrnorth
--------------------------------------------------