View Single Post
  #7   Report Post  
Posted to alt.home.repair
[email protected] ant30dio@yahoo.com is offline
external usenet poster
 
Posts: 63
Default Window AC Compressor won't shut off

OK, so your saying a relay and not the thermostat itself?
I will have to get some help removing this unit, as it's pretty big
and heavy.
I am assuming I have to remove the outer cover/shell.
Will there be just 1 relay in there?
I should be able to open the relay and see if it's stuck or burnt
together.
Thanks, Tony

On Jul 10, 11:17*am, Joe wrote:
On Jul 10, 10:11*am, " wrote:

snip
OK thanks, But would I still hear a "click" when I turn it (the
thermostat) from low to high?


Yes. The click is the coil pulling the relay armature down, but the
contacts could still be stuck solid. Try a new relay, and odds are
your problem could be gone.

Joe