View Single Post
  #3   Report Post  
Posted to sci.electronics.repair
nesesu nesesu is offline
external usenet poster
 
Posts: 119
Default Electric fence operation problem

On Jul 7, 6:46*am, "N_Cook" wrote:
2 stage derivation of (should be) 1800V pulses.
Fence had failure in the first stage probably due to intermittant corroded
battery supply contact.
Anyway the 15A 60V 8N06 powerFET blew along with an associated double diode
BAV23.
Replaced both and works to some extent. This FET has plenty of drive 5V of
pulses of repeat 3uS for the gate and about 3V ringing swing on the output
to the first step up transformer. I assume that is as to be expected, never
having the chance to see hot-side SMPS drive scope traces.
But rectified output only climbs to about 1V of DC before the final stage
(unreadable marking) thyristor discharges that supply into the second step
up transformer, but of course not even enough to get a glow on a 110V neon.