View Single Post
  #3   Report Post  
Posted to rec.woodworking
-MIKE- -MIKE- is offline
external usenet poster
 
Posts: 5,721
Default Craftsman Radial Arm Saw Motor Removal

On 2/3/10 1:49 PM, mikenj wrote:
I have a Sears Model Number 113.197150 radial arm saw that is late
eighties/early nineties vintage. The blade jammed into a piece of wood
and now the motor hums, but does not spin when I turn it on. I have
replaced the capacitor, but no luck. I wanted to take the motor off
and have an electric motor shop take a look at it, but I can't figure
out how to disconnect the power cord from the arm. Do I need to take
the arm apart to get to the wire connections or do I try to take the
motor apart? I can't figure out how to take the arm apart to get to
the wires.



I think there is a cable junction under the arm cover.

These diagrams should be a help in figuring out how to take it apart.

http://www.searspartsdirect.com/partsdirect/getModel!retrieve.pd?modelNumber=113.197150



--

-MIKE-

"Playing is not something I do at night, it's my function in life"
--Elvin Jones (1927-2004)
--
http://mikedrums.com

---remove "DOT" ^^^^ to reply