View Single Post
  #5   Report Post  
Posted to alt.home.repair
Walter R.[_2_] Walter R.[_2_] is offline
external usenet poster
 
Posts: 71
Default New installation trouble

I have run Malibu lights as far as 200'. Used 12 gauge copper wire.

The transformer should not be acting up because of a long wire run. This
would merely reduce the voltage at the end and dim the lights.

Sounds like a short in your wiring. The transformer shuts itself off when it
sees a short and then tries again after a few minutes.

--
Walter
www.rationality.net
-
"RBM" wrote in message
...

"mc" wrote in message
...
I am installing a new low voltage outdoor lighting system. There are 5
x 20w spot fixtures and one Malibu Lighting 200W transformer.

After installing the 5 lights, I laid out the 12-2 supply. The
furthest lights (2 on one post = 40w) are about 70' from the
transformer, and I hooked them up first.

With only those 2 lights attached, the transformer is cycling on/off
every 20-30 seconds.

The transformer, fixtures, lamps, cable, and connections are all new.
I took pains with the connections.

What am I missing? Please help.


Disconnect the fixtures and see if it still cycles. You may have a bad
transformer