View Single Post
  #9   Report Post  
Posted to alt.home.repair
Bob M. Bob M. is offline
external usenet poster
 
Posts: 375
Default A few questions about ridge vents

wrote in message
...
How do they attach it to the roof? Nails or screws? The ones that
were nailed down here in Florida came off the roofs easily during the
hurricanes. Do you have enough openings in the soffit to allow for
good air flow?




Ideally there should be more intake space than exhaust, and if the intakes
are covered with window-type screens, then that could reduce the "net free
area" by as much as 40%.

If the house has or will have soffit vents, they will need to install rafter
baffles as well, so the ceiling/attic insulation can go all the way to the
roof, yet still leave room for air to get from the soffit vents to the ridge
vent.

Also ask about rain infiltration. Some are rated for Miami-Dade county (FL)
hurricane standards, I believe the "air-vent II" is what I have (don't
remember the mfgr), and I think it's one of those that has 0% infiltration;
i.e. the attic remains totally dry inside even though the roof is about to
be ripped off....