View Single Post
  #1   Report Post  
Posted to alt.home.repair
[email protected] greenpjs@neo.rr.com is offline
external usenet poster
 
Posts: 132
Default Genie Excelerator

I installed a Genie Excelerator opener about 5 years ago. It has
worked well up until last night's nearby lightning strike. We lost a
variety of electronic things. The opener still works except for the
safety sensor system. The sending side is not lit and the opener acts
as one would expect - It opens just fine, but you must hold the button
to close it. Is there a common part that fails in these situations? I
can order a new board or a new set of safety sensors, but I thought
one of you might have a hint as to which one is more likely to have
failed. The voltage across the two terminals is only a few
millivolts. That points to the board, but I suppose one of the
sensors could have shorted. I think I'll go disconnect the sensors
and see what the voltage does. In the mean time, any input is
appreciated. ...Pat