View Single Post
  #1   Report Post  
Posted to sci.electronics.repair
Telespalla Bob Telespalla Bob is offline
external usenet poster
 
Posts: 17
Default Another problem on LG PDP 42V5

Hi, thanks to yours aid I have solved green dots noise in my 42V5 PDP,
adjusting two trimmers on Y-SUS board.
Now, one colleague with same LG chassis has this problem:
Image "spreaded" in vertical and Z-SUS board noisy.
Nothing changes adjusting the only trimmer present on this board... I
suspect IPM failure.
I tryed to exchange entire Z-SUS board with my one that work ok, and
image come back ok.
It have experience with this fail?
It is really IPM module failed, or I should seek some other problem?
Thanks in advance.



--
Prima di rispondermi devi togliere le dita dal naso!!! :-)