View Single Post
  #2   Report Post  
Posted to alt.home.repair
sanity sanity is offline
external usenet poster
 
Posts: 78
Default Amer Std commode bowl doesn't fill


"C & E" wrote in message
...
This is a Cadet model which, for those not familiar, will empty the bowl
of something like 26 golf balls. It has been in use for two years and
yesterday the tank fill valve stopped allowing any water into the tank so
I replaced it with a generic model from Blue Box. Now the toilet flushes
just fine but there is only enough water allowed back into the bowl to
cover the area immediately around the siphon hole. I tried different
settings on the valve but at the highest setting it is still shy of
filling the tanik by 1/2", I don't know if that 1/2" is even relevant to
the bowl level. Any ideas on the problem and the correction would be
appreciated.
TIA,
Chuck


If it's a Fluidmaster read the installation instructions. There is an
adjustment for the height of the Fluidmaster for shorter tanks and longer
tanks. Yours might be set on the shorter tank therefore not allowing the
tank to fill more. Look towards the bottom. There's a collar that you loosen
and then twist the base while holding the top.