View Single Post
  #2   Report Post  
Posted to sci.electronics.repair
Ron Ron is offline
external usenet poster
 
Posts: 314
Default Scored lines on speaker voice coil former

N_Cook wrote:
Due to dirt in use or at manufacture?
Carlsboro 10 inch ,open circuit, so burrowed in to explore. On the phenolic
cylinder that is the former for the voice coil . 4 pairs of scored
ines( stand out white against the amber colour of the phenolic). Each pair
about 6 to 7mm apart and arranged pairwise diametrically.

I suspect 4 pieces of sharp edged metal shim used in the original cone
setting and scored on removal. All the lines go axially , fully from one end
to the other , so if made in use would require the diaphragm (spider?) being
driven 10 mm into the magnet housing. Apart from the nearly symetrical
distribution of the lines.


Something isnt right here. Are the scored lines on the inside or the
outside of the coil former? Are the windings damaged by the scoring?
If it were the setting shims to blame for the scored lines - which seems
doubtful they`d use metal, all mine are plastic - they go on the inside
of the coil former. The windings are on the outside.

Take photo if you can.

Ron(UK)