Default Failure resulting in hole punched in GE CFL

"Michael A. Terrell" writes:

Sam Goldwasser wrote:

This one was rather strange, at least to me.

One of two horizontally mounted spiral GE CFLs in a semi-enclosed fixture
simply winked out. It's one I had repaired cracked solder joints on a year
or so ago so I figured time to resolder if the transistors/MOSFETs weren't
toast.

Checked all common suspects for shorts/opens as well as the lamp for
good filaments, no problesm found.

Resoldered some questionable joints - no sign of life.

Then I noticed IT - a dimple near one end of the tube and a resistor
lead could be inserted straight into the inside. A pinpoint on the
inside surface of the glass must have gotten really hot.

How often do you see that?



Not often, but then I usually just replace bad bulbs.


What fun is that?

--- sam | Sci.Electronics.Repair FAQ: http://www.repairfaq.org/
Repair | Main Table of Contents: http://www.repairfaq.org/REPAIR/
+Lasers | Sam's Laser FAQ: http://www.repairfaq.org/sam/lasersam.htm
| Mirror Sites: http://www.repairfaq.org/REPAIR/F_mirror.html

Important: Anything sent to the email address in the message header above is
ignored unless my full name AND either lasers or electronics is included in the
subject line. Or, you can contact me via the Feedback Form in the FAQs.