View Single Post
  #4   Report Post  
Posted to sci.electronics.repair
Andy Cuffe Andy Cuffe is offline
external usenet poster
 
Posts: 221
Default Fuse substitution

On Mon, 17 Nov 2008 10:49:46 -0800 (PST),
" wrote:

This set uses two 3.5A 125V pico fuses in the convergence circuit.
One is open. I don't have any pico fuses around the shop. After I
replace the STK's would there be any harm in using a standard AGC or
another fast blow 3.5A type in its place? Thanks, Lenny


It will work fine as long as you can insulate it so that it can't
short to anything, and if it doesn't matter how it looks.
Andy Cuffe