View Single Post
  #3   Report Post  
Posted to uk.d-i-y
robgraham robgraham is offline
external usenet poster
 
Posts: 1,730
Default Converting older 3 ph motor to delta

On 20 Sep, 22:41, "Andrew Mawson"
wrote:
"robgraham" wrote in message

...



I've the task of running a Harrison wood turning lathe with a 3/4 hp
3ph motor on single phase.


I've an electronic box which converts 240v single phase to 240v 3
phase and I've had running a modern 3ph motor, but the motor from

the
Harrison lathe ( Griphon from Brook Motors) is an old one and is
connected in star configuration for 415v operation.


Has anyone tackled taking an older motor such as this apart to get
access to the coil ends and reconnect as a delta connected motor? *I
can't imagine that motors of this age - possibly 60 years old - are
that much different in build but I don't have quite the confidence I
had in my teenage years for taking things apart and getting them

back
together again successfully so I'm looking for some words of
encouragement!!


Thanks
Rob


Rob,

Yes I've done it - it's fiddly and if the coils are shellac'd (which
they probably are) it makes getting the thing apart 'interesting'.
Make sure that you use wire and sleeving that will stand the
temperature and both lace it and shellac it to ensure no fretting. The
bigger the motor the easier it is. Smallest I've done was the suds
pump on a Colchester Student lathe - 1/6 hp iirc - all a bit tight in
there!

AWEM


Hi Andrew
Do I take it that you withdraw the rotor and work inside without
removing the coils ? Shellac I have in the form of I use for French
Polish - I take it that's the correct form? But what is suitable for
the re-lacing ?

I was just thinking that gentle application of meths will ease off the
existing shellac.

Many thanks - these are just the words I was looking for.
Rob