View Single Post
  #5   Report Post  
Posted to alt.home.repair
RBM[_2_] RBM[_2_] is offline
external usenet poster
 
Posts: 1,563
Default Replacing a wall switch that supplies power to a wall outlet


"Steve" wrote in message
...
I don't know a lot about house wiring. My wife and I moved into a
house a couple of years ago and are essentially trying to learn as we
go.

We have an air conditioner in our bedroom. Next to the air conditioner
is a wall outlet, but the wall outlet is dead (both the top and bottom
receptacles) and we've had to power the air conditioner via a long
extension cord. It would be much better to be able to power the AC via
the outlet that's right next to it, but I'm not entirely sure what's
wrong with that outlet.

It looks to me like the outlet is powered by a lever-action wall
switch. This sort of arrangement is present in a couple of other rooms
in our house...and the wall switch doesn't seem to be powering
anything *else* at the moment. However, assuming this is correct, no
power is reaching the wall outlet, no matter what position the switch
is in. I know because I have tested it. Power *is* present at the wall
switch, though. I know because I pulled the switch out of the wall and
used a multimeter to see that there is 24 volts on it (well, 23.9 to
be exact).

I'm guessing that the lever-action switch is simply defective and in
need of replacement. However, is there something I ought to be looking
for or considering before I run out and buy a replacement switch? Any
thoughts and/or advice will be appreciated.

Thanks!


Typically you'll have 120 volts at the switch, not 24. When you say
lever-action, what exactly do you mean? Some older installations around the
60's used low voltage (24 volt) momentary contact rocker switches, that
controlled latching relays for lighting and outlets. If this is the case,
it's possible that a relay is bad. It would help to have pictures as well