On Tue, 1 Jul 2008 11:07:11 +1000, the renowned "Phil Allison"
wrote:
"Eeysore"
Phil Allison wrote:
** See pics of AC supply adaptor:
Something here is not kosher.
Aside from my other comments .....
I'd like to see the clearance / creepage distances for that switch. Can
they seriously meet Class II ?
** Not an issue, as input and output circuits are both at mains voltages.
There is a serious safety issue with this device.
.... Phil
Only one issue?
Flammable plastic?
Non-FRP plastic melted through leaving a gaping hole and exposing
mains potential?
LED at mains potential without adequate insulation/creepage?
Best regards,
Spehro Pefhany
--
"it's the network..." "The Journey is the reward"
Info for manufacturers: http://www.trexon.com
Embedded software/hardware/analog Info for designers:
http://www.speff.com