Default What is wrong here ?



Oppie wrote:

"Oppie" wrote
"Phil Allison" wrote
"Eeysore"
Phil Allison wrote:

Something here is not kosher.

Well, it looks a bit tiny for 70W. More than a bit in fact. maybe they
meant 7W ?


** You are getting warm .....

Could be 70W if it was an autotransformer - no isolation and no earth
contact


I take that back - just read the symbol directory that Phil listed -
From the pictu
Double Insulated
Safety **Isolating** transformer - so it couldn't be an autotransformer.


Indeed. So 'dual bobbin' (typically) construction, with 6-8mm creepage
distance.


I can not match up the 110C symbol. Is this a thermal overload fuse rating?


IIRC, yes that's in internal non resettable fuse (without consulting the book).



Last symbol appears to be for 'Indoor Use Only' though it is not listed on
the Noratel list.


Yes, that's correct. Indoor use only.

HAH !

There's no amperage rating. I'm sure that *should* be there.