View Single Post
  #13   Report Post  
Posted to sci.electronics.repair
N_Cook N_Cook is offline
external usenet poster
 
Posts: 5,247
Default Safety issue ? -Phonic Power Pod 1062,mixer amp, from 2002

Eeyore wrote in message
...


N_Cook wrote:

There is a .47uF , 330 V polycarbonate between neutral and live on the

amp
side of the mains switch


Do you seriously mean POLYCARBONATE ? They are UNSAFE for across the mains

use
because they have very poor pulse tolerance. It should be a safety X-type

cap.

Graham



X1 type, large yellow cased , I thought were polycarbonate but I stand
corrected. I thought the critical factor was they had to be self-healing
which could be from pulse or surge.


--
Diverse Devices, Southampton, England
electronic hints and repair briefs , schematics/manuals list on
http://home.graffiti.net/diverse:graffiti.net/