View Single Post
  #9   Report Post  
Posted to sci.electronics.repair
N_Cook N_Cook is offline
external usenet poster
 
Posts: 5,247
Default Safety issue ? -Phonic Power Pod 1062,mixer amp, from 2002

second attempt

Ron(UK) wrote in message
...


Is there a capacitor strapped across the mains switch, or the input
socket? That would account for the clout he got when touching the mains
plug pins

Ron(UK)


There is a .47uF , 330 V polycarbonate between neutral and live on the

amp
side of the mains switch which would self discharge through the

transformer
in mS but nothing else except a fuse.


Are you sure it`s on the transformer side of the switch?

Ron



Mystery solved, yes that cap is on the mains cord side of the switch.
So what class of electric shock do you call that, high impedance , DC , of
little medical consequence in itself, but surprise effect could have
indirect consequences.


--
Diverse Devices, Southampton, England
electronic hints and repair briefs , schematics/manuals list on
http://home.graffiti.net/diverse:graffiti.net/