On Sun, 3 Feb 2008 20:03:22 -0800, "Joel Koltner"
wrote:

"legg" wrote in message
.. .
I'd try flipping C2 around to contact the ground at C4, to see if
there's a difference.


It makes the switcher go unstable. :-) Having already read some future
responses, though, I'm thinking that I then also want to cut the connection
going from the grounds on C2/R3/R5 back to the labeled ground test
point/via.


That would be the logical next step, given the results of the
iteration.