Kenmore Dryer: Heating Element is Perfect - but No Heat.
Follow up - for the benefit of all:
I just received the part and installed it - and the dryer is back to
working perfectly.
Thank you all for your guidance and help!
Sam
On Nov 13, 10:15 am, Smitty Two wrote:
In article om,
" wrote:
On Nov 11, 8:45 pm, BobK207 wrote:
3. THERMAL CUT-OFF (P/N 3398671) - open circuit !!!
Sounds like you've found the culprit! Did it looked "cooked"?
Thanks! I am pretty sure this is the part that needs replacement
although it doesn't look "cooked". I have verified with with of the
web sites that you provided that indeed the thermal cut-off part
should be normally conducting. It isn't, thus it is the culprit. I
will shortly order the part.
If possible, you could jumper the connections to that part (i.e., short
or bypass it) for a moment to test your theory before ordering the new
part.
|